CityCA
Posted
Aug 21, 2026
Oct 6, 2026
Wastewater Treatment Plants Influent Improvements Alternative Analyses (Request for Proposals)
Project includes professional engineering firm to provide professional engineering services for the study.
Description: Seeking for contract operations of the district's two tceq-permitted wastewater treatment plants (wwtps) and two county- permitted on-site sewage facilities (ossfs).
SchoolDistrict · TX, US
Original attachments and procurement documents tied to this bid.
No files attached to this RFP.
Many agencies add documentation later or require FOIA requests. Starbridge can automatically retrieve these files for you.
Request File RetrievalAdjacent opportunities open for bidding right now.
CityCA
Posted
Aug 21, 2026
Oct 6, 2026
Project includes professional engineering firm to provide professional engineering services for the study.
CityTX
Posted
-
Sep 4, 2026
Provide professional engineering and related services for wastewater treatment plant improvements and other associated wastewater infrastructure improvements.
CityIN
Posted
Aug 7, 2026
Sep 10, 2026
Project scope consists of the construction of a new mechanical screen at the WWTP; converting the existing main lift station to a submersible or in-line pump station; site piping; electrical; instrumentation and controls; and all other work
Orange Water And Sewer Authority
Special DistrictNC
Posted
Aug 17, 2026
Sep 25, 2026
Secondary Clarifier #3 is an 85-foot diameter H40A HT Tow-Bro sludge collector clarifier, originally constructed in 1983. The interior clarifier mechanical equipment— including the center-drive mechanism, trusses, header assembly, manifold, influent well, surface skimmers, and scum beach—was replaced approx. five years ago as part of a capital improvement project. The scope of work includes: 1. Temporarily supporting the existing drive mechanism before disconnecting the center cage 2. Rebalancing the drive and replacing the grout between the top of the center pier and the bottom of the drive. 3. Heating up and bending the truss mounting bar back into its original position 4. Replacing manifold seals per manufacturer specifications 5. Mounting a new fluidizing vane to the bottom of the existing header by drilling new holes adjacent to the current ones 6. Installing additional counterweights per the manufacturer’s recommendations 7. Ensuring the drive is fully leveled and up to spec before connecting back to the main cage 8. Coordinating with equipment supplier vendor for certification that repairs were done correctly, and witness testing and performance testing for startup purposes.
Decision makers connected to this RFP from East Central Independent School District.