School DistrictOH
Posted
Nov 2, 2026
Dec 4, 2026
Wooster HS VAV Replacement RFP
Replacement of variable air volume (VAV) systems at Wooster High School.
Description: Status Accepting Bids Prebid Date 11/24/26 10:00am Bid Date 12/4/26 11:00am Company Fanning / Howey Associates, Inc Location Wooster, OH Replacement OrderRemove Order this entire project for $135.00 This is available for download to registered users. Log in now Details Plans Specs Plan Holders 1. Sets may be purchased for the non-refundable amount of $135 per set payable to DC Reprographics. 2. Sets may be ordered by clicking the order button above and proceed to view your shopping cart and checkout. 3. Shipping and handling is $25 per set payable to DC Reprographics. NO UPS OR FED-EX NUMBERS WILL BE USED. 4. In order for your sets to ship, you may pay with Visa, AmEx, Mastercard
School · OH, US
Solicitation files and supporting documents for this bid.
RFP documents aren’t available here yet.
Our team can help you find the original solicitation documents.
Request File RetrievalAdjacent opportunities open for bidding right now.
School DistrictOH
Posted
Nov 2, 2026
Dec 4, 2026
Replacement of variable air volume (VAV) systems at Wooster High School.
Higher EducationOH
Posted
Oct 28, 2026
Nov 16, 2026
Request for Qualifications (CM at Risk Contract) State of Ohio Standard Forms and Documents Administration of Project: Local Higher Education Project Name Wooster - Fisher Aud Renovation Response Deadline 11/16/2026 2:00 PM local time Project Location 1680 Madison Avenue Project Number OSU-200473 City / County Wooster / Wayne Project Manager Amy Kaspar Owner The Ohio State University Contracting Authority The Ohio State University Delivery Method CM at Risk Prevailing Wages State No. of paper copies requested (stapled, not bound) 0 No. of electronic copies requested (PDF) 1 Submit the Statements of Qualifications (Form F110-330) via email to: Wooster_-_Fisher_Auditorium.01_Selection@docs.e-builder.net In the subject line, include the project number and name for the RFQ you are responding to. See Section G of this RFQ for additional submittal instructions. Submit all questions regarding this RFQ in writing to Amy Kaspar at kaspar.2@osu.edu with the project number and name included in the subject line (no phone calls please). Questions will be answered and posted to Opportunities page on the OFCC website at Project Opportunities on a regular basis until one week before the response deadline. The name of the party submitting a question will not be included on the Q&A document. Project Overview A. Project Description The Fisher Auditorium building is centrally located on the CFAES Wooster Campus. The building will be converted to "Campus Commons", with the original Fisher Auditorium remaining within the building. The building's renovation will play a critical role in the vision to create a "Heart of Campus, with goals to improve the sense of community, access to campus resources, and opportunities for collaboration. The building was constructed in 1968 and renovated in 2000. The existing Fisher Auditorium is used for numerous University, industry partner and community events. The Auditorium is not included in the proposed renovation. This project focuses on creating Fisher Commons in approximately 18,000 SF of space surrounding the Auditorium. Currently, this space includes exhibit space, library, offices, conference/classrooms, catering food service, general administration, and auxiliary services. It will be renovated to include a library, learning lab, bookstore, offices, food service, dining, and lounge spaces. The building has multiple entry points, and it is connected to the Shisler (Conference) Center via a corridor on the north elevation. To reorient the building's main entrance toward the center of campus, improve accessibility, and enhance circulation, an approximately 3000SF addition is being considered to add to the north side of the building, connected to the corridor that leads to the Shisler Center. Site and accessibility improvements will occur at the new north entrance and the west portico. Professional design services will be completed by The Collaborative, Inc. and have been acquired by the Contracting Authority under a separate contract. The Program of Requirements ("POR") will be validated as a part of this project by the Architect/Engineer ("A/E"). All aspects of the project and related issues will be implemented and operated consistent with the Contracting Authority/Owner's policies and procedures. This project is required to be designed and delivered within a collaborative BIM-enabled environment following The Ohio State University BIM Project Delivery Standards. The Primary firm submitting for the project will be required to have the BIM expertise capable of meeting the aforementioned standards. The Ohio State University BIM Project Delivery Standards can be accessed via the OSU FOD website: BIM Project Delivery Standards. The minimum required BIM Use Cases for this project are noted below. Details on the BIM Uses Cases are outlined in Section 2 of the Ohio State University BIM Project Delivery Standards. F170-01-2022-MAR Publish Date: 10/28/2026 Page 1 of 6 Design BIM Use Case Required Additional Notes 2.3.1.1. Model Authoring - Design Intent BIMs (Required for the Architectural X team and the Engineering team) 2.3.1.2. Model Authoring - Design Intent BIMs (Required for the architectural team, preferred for the engineering team) 2.3.2. Existing Conditions Documentation/Modeling 2.3.3. Program of Requirements (PoR) Validation 2.3.4. Site Design 2.3.5. Model Based User Group Meetings/Reviews 2.3.6. Sustainability (Energy Modeling/Simulation and Performance)/ Design Simulation/Analysis 2.3.7. Clash Prevention X 2.3.8 Quantity Schedule Construct BIM Use Case Required Additional Notes 2.4.1. Model Authoring - Trade Coordination BIMs X 2.4.2. Model Authoring - Shop/Fabrication BIMs Preferred, not required 2.4.3. Clash Detection X 2.4.4. Model-based Scheduling (Sequencing/Simulation) 2.4.5. Model-based Estimating (Quantification/Cost Estimating) 2.4.6. Site Analysis Planning The minimum required deliverables for this project are noted below. Details on the BIM deliverables are outlined in Section 4 of the Ohio State University BIM Project Delivery Standards Deliverable Required BIM Execution Plan X Design Intent BIMs X Revit Model Rule Set Results X Interim Architectural and Structural Conformed Design Intent BIMs X Project Base Point X Conformed Design Intent BIMs X Interim Asset Worksheet X Final Asset Worksheet X This project includes asset tagging. The Primary firm submitting for the project is required to have the expertise capable of meeting this prerequisite and is responsible to support their subcontractors to meet this requirement. The Asset Tagging Process Diagram, Asset Worksheet Template, and LOD Matrix can be accessed via the OSU FOD website under Design Guidelines, Specifications, Standards; Specifications and Standards; Building Information Modeling (BIM). B. Scope of Services The project and construction budget as listed in this RFQ is estimated. The project has been approved for design and preconstruction services only. This request is for Construction Manager at Risk ("CM") to assist with preconstruction to establish the schematic design concept and begin design development. The university may amend the CM contract upon approval for construction documents, bidding, construction contract administration and post-construction services. The selected Construction Manager at Risk, as a portion of its required Scope of Services and prior to submitting its proposal, will discuss and clarify with the Contracting Authority/Owner, the breakdown of the Agreement detailed cost components, to address the Owner's project requirements and refine the project schedule. Participate in the Encouraging Diversity, Growth & Equity (EDGE) Program as required by statute and the Agreement. As required by the Agreement, and as properly authorized, provide the following categories of services: provide constructability review comments on documents produced by the A/E during the Schematic Design, Design Development, and Construction Document stages; develop and maintain estimates of probable construction cost, Target Value Budget/Target Value Design, project schedules, and construction schedules; lead and manage the Subcontractor Prequalification and Bidding process, Construction and Closeout Stage. Refer to the Ohio Facilities Construction Manual for additional information about the type and extent of services required for each. A copy of the standard Agreement can be obtained at the OFCC website at Construction Manager at Risk Agreements. F170-01-2022-MAR Publish Date: [leave blank] Page 2 of 6 The selected CM will be required to sign the standard agreement. No modifications to the requirements in the agreement will be accepted. Required Professional Liability Insurance will be per General Conditions Articles 10.3.7 and 10.3.8. The project shall follow the applicable University Sustainability Standards. The project team (Owner / A/E / CM) will be required to utilize e-Builder, the University's Project Management System, for all compatible services required by the University. The preconstruction and construction services are generally described below. Subcontracts including but not limited to Plumbing, Fire Protection, HVAC, Electrical and AV/Technology will be awarded by the CM to prequalified vendors using a competitive process. The parties will engage in an "open book" pricing method in which all subcontracted work shall be based upon competitive pricing that will be reviewed by the Contracting Authority/Owner, the A/E and the CM. The Contracting Authority/Owner shall have access to all books, records, documents and other data in the CM's possession related to itself, its subcontractors and material suppliers pertaining to bidding, pricing or performance of the Agreement. Preconstruction Services: The CM will work cooperatively with the Contracting Authority/Owner, A/E, and Project Team, and will provide, among other services, schedule development, estimate development, Guaranteed Maximum Price (GMP) proposal, subcontractor prequalification and bidding, constructability review, permits, budgeting, Target Value Budget/Target Value Design, and preconstruction planning throughout the preconstruction stages. When the drawings and specifications are at the stage of completion specified in the Agreement, such partially completed documents (the "Basis Documents") shall be provided to the CM, together with the A/E's detailed listing of any incomplete design elements and the A/E's statement of intended scope with respect to such incomplete elements (the "Design Intent Statement"). Contingent upon the Contracting Authority's approval of the GMP, the parties will enter into an amendment to the Agreement establishing the Contract Sum ("GMP Amendment"). If the proposed Contract Sum exceeds the Project Budget established for construction, then the Contracting Authority may terminate the agreement with the CM and seek proposals from other firms for completion of the Project. Construction Services: The CM shall construct the Project pursuant to the construction documents and in accordance with the schedule requirements. The CM shall hold all subcontracts and shall be fully responsible for the means and methods of construction, project safety, project completion within the schedule agreed upon in the preconstruction phase, compliance with all applicable laws and regulations including monitoring compliance with all EDGE, equal employment, and prevailing wage requirements, and submitting monthly reports of these activities to the Contracting Authority. All subcontracts shall be on the subcontract form prescribed by OAC Section 153:1-03-02. The Contracting Authority reserves the right to approve the CM's selection of subcontractors and any supplemental terms to the form subcontract. The Ohio State University is dedicated to providing a safe and healthy environment for students, patients, staff, visitors and contractors. While not exclusive, guidelines governing safety expectations for construction/ renovation projects within Ohio State buildings are set forth in the Building Design Standards Appendix V and are summarized here: under the section titled "Construction Site Safety Requirements." Closeout Services: The closeout for this project is required to be delivered in an electronic cloud-based format using e- Builder Project Management System and adhere to The Ohio State University Project Closeout Standards. The Ohio State University Project Closeout Standards can be accessed via the OSU FOD vender resource website under Post Construction / Close Out. For purposes of completing the Relevant Project Experience Matrix in Section F of the Statement of Qualifications (Form F110-330), below is a list of relevant scope of work requirements for this RFQ: 1. Target Value Budgeting During Preconstruction; Demonstrated experience providing real-time pricing feedback, value analysis, and budget reconciliation to support owner decision-making. 2. Schedule Milestones; Experience supporting owner funding approvals, budget authorizations, GMP development, and procurement schedules. 3. Experience with renovation projects on University Campuses in the past 15 yrs. 4. Experience as Construction Manager at Risk (or DB) at The Ohio State University or State of Ohio Administered Projects - and indicate role on all projects. For the purpose of the selection of 10 Relevant Projects in Section F of the Statement of Qualification (Form F110-330), projects must have been completed by the Construction Management Firm. C. Funding / Estimated Budget Total Project Cost $16,500,000 State Funding $14,730,118 Construction Cost $8,900,000 Other Funding $1,769,000 F170-01-2022-MAR Publish Date: [leave blank] Page 3 of 6 D. Anticipated Schedule E. EDGE Participation Goal CM Preconstruction Services Start 03 / 2027 Percent of the CM's total compensation Construction Stage Notice to Proceed 11 / 2027 excluding CM's Contingency* 5.0% Substantial Completion of all Work 04 / 2029 *Preconstruction Stage Compensation plus Contract Sum CM Services Completed 06 / 2029 minus CM's Contingency F. Evaluation Criteria for Selection Selection Criteria: The CM will be selected using (i) qualifications-based process during the Request for Qualifications (RFQ) stage to develop a short list and (ii) best value process during the Request for Proposal stage. The qualifications- based criteria for the RFQ is included in this announcement. The best value criteria used in evaluating proposals from short listed firms will include such factors that are determined to derive or offer the greatest value to the State and Owner, combining both qualifications and fee. Short List: Each firm responding to this RFQ will be evaluated and selected based on its qualifications and the qualifications and experience of the particular individuals identified as the candidate's proposed team for the Project. After evaluating the responses to this RFQ, the Contracting Authority will select a short list of no fewer than three candidates that it considers to be the most qualified, except if the Contracting Authority determines that fewer than three firms are qualified, it will only select the qualified firms. Request for Proposal: The short-listed firms shall be sent a Request for Proposal ("RFP") that will invite the firms to submit pricing proposals containing their proposed preconstruction stage compensation, construction stage personnel costs, itemized construction stage general conditions costs, construction stage contingency percentage, and construction stage fee percentage. The short-listed candidates will also receive (i) form of Agreement with the Contracting Authority containing the contract terms and conditions, (ii) set of the most recent design documents and (iii) proposed Project schedule. Pre-Proposal Meeting: Prior to submitting a response to the RFP, the short-listed firms will be invited to meet individually with the Contracting Authority/Owner. The purpose of the pre-proposal meeting is to permit the short-listed firms an opportunity to ask the Contracting Authority/Owner questions in an individual setting to help the firms prepare their responses to the RFP. The Contracting Authority will notify each short-listed firm to schedule individual times for the pre- proposal meetings. At the pre-proposal meeting, short-listed firms will be required to submit the completed Contractor Pre-Work Evaluation form, available here under the section titled "Construction Site Safety Requirements." Interview: After submitting responses to the RFP, the short-listed firms will be interviewed by the Contracting Authority/Owner. The purpose of the interview will be to meet the proposed Project team, become familiar with key personnel, and understand the project approach and ability to meet the stated objectives for the Project. Please be prepared to discuss with specificity the firm's capacity to conduct this work in compliance with the timetable, budget and EDGE expectations. The Contracting Authority will notify each short-listed firm to schedule individual times for the interviews. Selection Schedule: Tentative schedule is subject to change. Qualifications Due 11/16/2026 RFP issued to the Short-Listed Firms 11/23/2026 Proposals Due 12/10/2026 Interviews 12/15/2026 Selection of CM 12/17/2026 Cancellation and Rejection: The Contracting Authority reserves the right to reject all proposals and cancel at any time for any reason this solicitation, any portion of this solicitation or any phase of the Project. The Contracting Authority shall have no liability to any proposer arising out of such cancellation or rejection. The Contracting Authority reserves the right to waive minor variations in the selection process. Interested firms are required to address their BIM project delivery experience and how they will implement Building Information Modeling ("BIM") on the project by documenting: • The ability for the entire team to effectively collaborate and share models and data. • Each discipline's model manager and their relevant experience. • How the CM will support a subcontractor that does not have sufficient BIM experience to meet the above expectations. F170-01-2022-MAR Publish Date: [leave blank] Page 4 of 6 Interested CM firms are required to submit the Commitment to Participate in the EDGE Business Assistance Program form in its Statement of Qualifications (Form F110-330) submitted in response to the RFQ, to indicate its intent to contract with and use EDGE-certified Business Enterprise(s), as a part of the CM's team. The Intent to Contract and to Perform and / or waiver request letter and Demonstration of Good Faith Effort form(s) with complete documentation must be attached to the CM's Proposal. Both forms can be accessed via the OFCC website at Procurement Forms. The Intent to Contract and to Perform form is again required at the Fee Proposal stage. If the CM firm intends to receive points for exceeding the EDGE Participation Goal, it must provide BOTH a completed Commitment to Participate form AND a completed Statement of Intent to Contract and to Perform forms signed by both parties with its Statement of Qualifications. For all Statements of Qualifications, please identify the EDGE-certified Business Enterprises, by name, which will participate in the delivery of the proposed professional services solicited in the RFQ. Interested CM firms must indicate on their Statement of Qualifications, the locations where their services will be performed in the spaces provided or by attachment in accordance with the requirements of Executive Order 2019-12D related to providing services only within the United States and the requirements of Executive Order 2022-02D prohibiting purchases from or investment in any Russian institution or company. Failure to do so may cause their Statement of Qualifications to be rejected. G. Submittal Instructions Firms are required to submit the current version of Statement of Qualifications (Form F110-330) available via the OFCC website at Procurement Forms. Electronic submittals should be combined into one PDF file saved with the form name, project number listed on the RFQ and your firm's name (ex. F110-330_OSU-nnnnnn_Firm Name). Use the "print" feature of Adobe Acrobat or similar software for creating a PDF rather than using a scanner. If possible, please reduce the file size of the PDF. In Acrobat, go to Advanced, then PDF Optimizer. Also, please insert the project number and name in the email subject line. Statements of Qualifications must be submitted electronically by email. Submittals are limited to one email with a maximum file size of 25 MB. Unless otherwise noted or exempt, all documents submitted to the Contracting Authority in response to this RFQ and subsequent RFP are public and will be available for inspection at the conclusion of the selection process. The following information shall remain confidential and will not be released: (1) Proposal Form(s), except for cost category subtotals which will be transferred to the Best Value Rating Form; (2) Financial Capacity; and (3) Bonding/Insurance. Proposers are requested to submit the following information in response to this RFQ within Section H of Form F110-330. 1. Summary: Provide a summary, on one page or less, describing why your firm/team is the most qualified for the Project. 2. Bonding/Insurance: Provide evidence of capacity to provide bonding in the amount of the construction budget (e.g. a letter from your Surety agent stating that one or more Sureties will issue Bonds in the amount of the construction budget if your team is selected) and a copy of the firm's certificate of insurance showing the firm's current limits of liability for commercial general liability, employer's liability, business automobile liability, and professional liability insurance. 3. Management Systems: Describe the scheduling and cost control systems the firm would propose to use for the Project. a. The project team (Owner / AE / CM) will be required to utilize eBuilder, the University's Project Management System, for all compatible services required by the University. Please comment on incorporating this system into your construction services and in conjunction with your prescribed corporate project management systems, if any. 4. Self-Performed Work: Indicate whether the firm intends to self-perform any work on the Project through a competitive process and, if so, the nature of the work and capability to self-perform. 5. Estimating: Demonstrated track record of performance of in-house estimating on projects comparable to the Project. 6. Scheduling: Demonstrated track record of performance of managing projects to the original schedule. Firms are requested to identify professional registrations, memberships and credentials including but not limited to: LEED GA, LEED AP, LEED AP+, CCCA, CCM, CCS, CDT, CPE, DBIA, and any other appropriate design and construction industry credentials. Identify that information on the resume page for individual in Block 22, Section E of the F110-330 form. F170-01-2022-MAR Publish Date: [leave blank] Page 5 of 6 CM at Risk Selection Rating Form State of Ohio Standard Forms and Documents Project Name Wooster - Fisher Aud Renovation Proposer Firm Project Number OSU-200473 City, State, Zip Selection Criteria Value Score [Selection criteria and scoring matrix included as published] Notes: Evaluator: Name Signature Date F170-01-2022-MAR Publish Date: 10/28/2026 Page 6 of 6
Posted
Oct 19, 2026
Nov 19, 2026
Renovation of four trap fields, including new trap houses with associated site work, and construction of a new shooting shed and office to support Shooting Range programs and activities.
Jefferson County School District
School DistrictAL
Posted
Jun 4, 2026
Nov 17, 2026
In general, the project scope includes, but is not limited to, select demolition of existing buildings and site utilities, installation of new site utility and road infrastructure, and the construction of a new +/-350,000 GSF multi-story replacement high school in Pinson, AL for the County Board of Education (JEFCOED). The building construction consists of poured-in-place concrete retaining walls, load bearing cmu with brick and EIFS veneer, prefabricated concrete plank and composite steel floor framing, asphalt shingle roofing on light gauge metal trusses, TPO membrane low-slope roofing on metal deck and steel joists, and full MEP building system infrastructure.
Decision makers connected to this RFP from Wooster High School.