UPS System Maintenance & PM Requirements RFP

Description: One (1) year full maintenance coverage: (2 Liebert UPS & 5 STS)   Unscheduled Services 0800-1700 Mondays - Fridays Emergency Service 1700-0800 Monday – Friday and 0700-0700 Saturdays and Sundays and Holidays. All parts, labor and expenses Response time: four (4) hours or less   One PM Inspections: (2 Liebert UPS @ 5 STS)   System overview with customer and detailed inspection report   Vendor must be an authorized service provider for Liebert power product lines (uninterruptible power supply/battery, static transfer switch, etc.) Documentation showing authorized service provider status must be  submitted with quote. STATIC TRANSFER SWITCH  SCOPE OF WORK Perform a complete visual inspection of the equipment, including sub-assemblies, wiring harnesses, contacts, cables and major components. Check all mechanical connections for tightness and heat discoloration, making corrections where necessary. Clean foreign material and dust from internal compartments. Perform a status check of alarm circuits. Calibration of the equipment to meet manufacturer’s specifications. Operational checkout of the system to include transfers and proper status indications. Install or perform Engineering Field Change Notices (FCN) as necessary. Return unit to operational service with normal load then measure and verify display indications. Perform additional checks as consistent with customary commercial practice. Review system performance with customer to address any questions and to schedule any repairs. Provide a detailed written report noting any deficiencies and corrective action needed, taken and/or planned.     BATTERY SYSTEM SCOPE OF WORK   Clean normal cell top dirt accumulation. Measure and record the total battery float voltage and charging current. Measure and record the overall AC ripple voltage. Visually inspect the jars and covers for cracks and leakage. Visually inspect for evidence of corrosion. Measure and record the ambient temperature. Verify the integrity of the battery rack/cabinet. Measure and record 100% of the jar temperatures. Measure and record the float voltage of all jars. Measure and record all internal ohmic readings. Re-tighten all connections to the battery manufacturer's specifications, if required. Measure and record all battery connection resistances in micro-ohms, when applicable. Refurbish cell connections as deemed necessary. Check integrity of battery cabinet. Check for NO-OX grease or oil on all connections (if applicable). Check battery jars for proper liquid level (if flooded cells). Check for corrosion on all the terminals and cables. Examine the physical cleanliness of the battery room and jars. Measure and record DC bus ripple voltage (if applicable). Measure and record total battery float voltage. Perform additional checks as consistent with customary commercial practice. Review system performance with customer to address any questions and to schedule any repairs. Provide a detailed written report noting any deficiencies and corrective action needed, taken and/or planned.   UNINTERRUPTIBLE POWER SYSTEMS SCOPE OF WORK   Perform temperature check on all breakers, connections, and associated controls. Repair and/or report all high temperature areas. Perform a complete visual inspection of the equipment including subassemblies, wiring harnesses, contacts, cables, and major components. Check air filters for cleanliness. (if applicable) Check rectifier and inverter snubber boards for discoloration. Check power capacitors for swelling or leaking oil. Check for DC capacitor vent caps that have extruded more than 1/8". (if applicable) Record all voltage and current meter readings on the module control cabinet or the system control cabinet. Measure and record harmonic trap filter currents. Check the inverter and rectifier snubbers. Check all nuts, bolts, screws, and connectors for tightness and heat discoloration. Check fuses on the DC capacitor deck for continuity (if applicable). With customer approval, perform operational test of the system including unit transfer and battery discharge. Calibrate and record all electronics to system specifications. Check or perform Engineering Field Change Notices (FCN) as necessary. Measure and record all low-voltage power supply levels. Record phase-to-phase input voltage and currents. Perform additional checks as consistent with customary commercial practice. Review system performance with customer to address any questions and to schedule any repairs. Provide a detailed written report noting any deficiencies and corrective action needed, taken and/or planned.       UPS SYSTEM INFO   Liebert s610 SMS UPS                    Model # UDA63154A36AD68   Tag # 1303573   Battery: Manufacturer: ENERSYS                            No of Jars: 40 Model: HX505-FR                                     Cells per Jar: 6 Battery Type: VRLA                                  Cells per string: 240   MBCPM   Model# U36MB15430AA25S           TAG# 1303576     Liebert s610 SMS UPS                    Model # UDA63154A36AD68   Tag # 1303573   Battery: Manufacturer: ENERSYS                            No of Jars: 40 Model: HX505-FR                                     Cells per Jar: 6 Battery Type: VRLA                                  Cells per string: 240

Buyer
Escambia County

County · FL, US

Released
Nov 23, 2026
Closes
Dec 10, 2026(14 days left)
See your top accountsScan your site in seconds. Starbridge identifies your ICP and surfaces emerging opportunities from board meetings, job changes, new grants, contract expirations, RFPs, and more.
See your top 10 accounts