Posted
Jan 20, 2026
Dec 31, 2026
Stern Grove Trees (Request for Quotes)
Tree work/services. Arborist services, tree removal (2 large + 1 small eucalyptus), debris removal, site protection, and compliance with GreenHalo waste‑diversion reporting.
Description: Repair services for the grove 530 rough terrain crane, #2941, serial # 229418. The repair work will involve restoring the counterweight attachment by welding, repositioning the counterweight and securely bolting it to the crane.
SpecialDistrict · PA, US
Adjacent opportunities open for bidding right now.
Posted
Jan 20, 2026
Dec 31, 2026
Tree work/services. Arborist services, tree removal (2 large + 1 small eucalyptus), debris removal, site protection, and compliance with GreenHalo waste‑diversion reporting.
University Of South Carolina Columbia
Higher EducationSC
Posted
Oct 28, 2026
Dec 2, 2026
Repair/replace water-damaged wood flooring in the gymnasium (16 Ft by 105 Ft), restore affected court markings, and refinish (screen & recoat) the entire gymnasium floor.
Posted
Oct 16, 2026
Nov 23, 2026
Telephone, in repair/modification of, NSN: 7G-5805-015400342, tdp ver 002, qty 7 ea.7 ea, telephone, NSN: 5805015400342.
Special DistrictIN
Posted
Oct 29, 2026
Nov 19, 2026
Sanitary Sewer Repair at 1608 Broadway in the City of Gary, IN. Furnish all labor, materials, tools, equipment, superintendence, and all necessary incidentals for the repair of sanitary sewer pipe. Manhole No. 507 Sewer Invert Depth is ± 13.7 Manhole No. 508 Sewer Invert Depth is ± 13.9 POINT REPAIR Remove and replace existing 15-inch diameter pipe with 15-inch diameter PVC SDR 35 ± 30-linear feet from Manhole No. 508 going towards Manhole No. 507. CIPP LINING CIPP line existing 15-inch diameter pipe x 190 linear feet starting from Manhole No. 508 to Manhole No. 507. POINT REPAIR Remove and replace existing 15-inch diameter pipe with 15-inch diameter PVC SDR 35 ± 30-linear feet from Manhole No. 508 going towards Manhole No. 507. Contractor shall ensure pipe penetrations are sealed and watertight. Contractor shall connect new pipe to existing good pipe with a watertight connection. Connect new pipe to existing PVC pipe with neoprene rubber coupling with stainless steel straps or coupling provided by the manufacturer and approved by the owner. When adjoining new pipe to existing, the maximum space between the abutting pipes shall be 1/8 inches or less. CIPP LINING CIPP line existing 15-inch diameter pipe x 190 linear feet starting from Manhole No. 508 to Manhole No. 507. The CIPP liner shall extend 4-inches into existing manholes. The Contractor shall install a pre-liner and/or perform chemical grouting of infiltration points as necessary
Decision makers connected to this RFP from Southeastern Pennsylvania Transportation Authority.
Solicitation files and supporting documents for this bid.
RFP documents aren’t available here yet.
Our team can help you find the original solicitation documents.
Request File Retrieval