Posted
Oct 16, 2026
Nov 23, 2026
Telephone, in Repair/Modification of - Mechanicsburg (Request for Quotes)
Telephone, in repair/modification of, NSN: 7G-5805-015400342, tdp ver 002, qty 7 ea.7 ea, telephone, NSN: 5805015400342.
Description: Repair/replace water-damaged wood flooring in the gymnasium (16 Ft by 105 Ft), restore affected court markings, and refinish (screen & recoat) the entire gymnasium floor.
HigherEducation · SC, US
Adjacent opportunities open for bidding right now.
Posted
Oct 16, 2026
Nov 23, 2026
Telephone, in repair/modification of, NSN: 7G-5805-015400342, tdp ver 002, qty 7 ea.7 ea, telephone, NSN: 5805015400342.
Special DistrictIN
Posted
Oct 29, 2026
Nov 19, 2026
Sanitary Sewer Repair at 1608 Broadway in the City of Gary, IN. Furnish all labor, materials, tools, equipment, superintendence, and all necessary incidentals for the repair of sanitary sewer pipe. Manhole No. 507 Sewer Invert Depth is ± 13.7 Manhole No. 508 Sewer Invert Depth is ± 13.9 POINT REPAIR Remove and replace existing 15-inch diameter pipe with 15-inch diameter PVC SDR 35 ± 30-linear feet from Manhole No. 508 going towards Manhole No. 507. CIPP LINING CIPP line existing 15-inch diameter pipe x 190 linear feet starting from Manhole No. 508 to Manhole No. 507. POINT REPAIR Remove and replace existing 15-inch diameter pipe with 15-inch diameter PVC SDR 35 ± 30-linear feet from Manhole No. 508 going towards Manhole No. 507. Contractor shall ensure pipe penetrations are sealed and watertight. Contractor shall connect new pipe to existing good pipe with a watertight connection. Connect new pipe to existing PVC pipe with neoprene rubber coupling with stainless steel straps or coupling provided by the manufacturer and approved by the owner. When adjoining new pipe to existing, the maximum space between the abutting pipes shall be 1/8 inches or less. CIPP LINING CIPP line existing 15-inch diameter pipe x 190 linear feet starting from Manhole No. 508 to Manhole No. 507. The CIPP liner shall extend 4-inches into existing manholes. The Contractor shall install a pre-liner and/or perform chemical grouting of infiltration points as necessary
Posted
Oct 16, 2026
Nov 20, 2026
Repair/modification of generator, pulse, NSN 7R-6625-014262651-XE, TDP VER 016, REF NR 459659-2, QTY 200 EA.
Southeastern Pennsylvania Transportation Authority
Special DistrictPA
Posted
Oct 29, 2026
Nov 3, 2026
Repair services for the grove 530 rough terrain crane, #2941, serial # 229418. The repair work will involve restoring the counterweight attachment by welding, repositioning the counterweight and securely bolting it to the crane.
Solicitation files and supporting documents for this bid.
Decision makers connected to this RFP from University Of South Carolina Columbia.