Project consists of installing approx 2,140 LF of 12" zinc coated ductile iron pipe (dip), 1,165 LF 8" zinc coated dip, rehabilitate 310 LF of the existing 6" cast iron water main along drive via cured-in-place pipe (CIPP), and tie-in connections to replace existing 6" cast iron and 4" PVC water mains. Work also includes installation of, air release valves, fire hydrants, service connections; abandoning of existing water main, vault, and appurtenances; surface restoration including slurry seal and striping among other appurtenances work.
Starbridge can help you:
Pain points mentioned in board meetings and strategic plans
Instantly outline and draft all requirements
Bring in your USPs and exploit competitor gaps
Starbridge can help you:
Get ahead of RFPs — target accounts planning budget or ending contracts soon
Accounts with contract expirations, meetings mentioning your product, grants, budget changes and more
Starbridge.ai books 30 - 40% of leads into meetings
No files attached to this RFP.
Many agencies add documentation later or require FOIA requests. Starbridge can automatically retrieve these files for you.
Release: -
Close: Feb 5, 2026
Avenue improvements and water main.
AvailableWork includes approx 7,595 LF 8" DIP class 52 with polyethylene wrap water main; 300 LF 8" DIP class 52 with polyethylene wrap water main by directional bore; 2,640 LF 1" PEX water service pipe by directional bore; 10 EA 6" PVC SDR-26 D2241 sanitary sewer service repair. See outside link.
Posted Date
Dec 22, 2025
Due Date
Feb 9, 2026
Release: Dec 22, 2025
Close: Feb 9, 2026
Work includes approx 7,595 LF 8" DIP class 52 with polyethylene wrap water main; 300 LF 8" DIP class 52 with polyethylene wrap water main by directional bore; 2,640 LF 1" PEX water service pipe by directional bore; 10 EA 6" PVC SDR-26 D2241 sanitary sewer service repair. See outside link.
AvailableThe project consists of installing approx. 6,720 LF of 6" PVC C900 WM, 2,770 LF of 8" PVC C900 WM, 31 Ea fire hydrants, 1 Ea fire hydrant relocation, 23 Ea of 6" gate valve in 4' vault, 9 Ea of 8" gate valve in 4' valve vault, 118 Ea water service connections, 125 LF remove and replace culvert, 300 LF of 12" water main quality storm sewer, 50 LF of 18" water main quality storm sewer, 14,000 SY topsoil furnish and place, and all other work necessary to complete the improvements.
Posted Date
Jan 5, 2026
Due Date
Feb 9, 2026
Release: Jan 5, 2026
Close: Feb 9, 2026
The project consists of installing approx. 6,720 LF of 6" PVC C900 WM, 2,770 LF of 8" PVC C900 WM, 31 Ea fire hydrants, 1 Ea fire hydrant relocation, 23 Ea of 6" gate valve in 4' vault, 9 Ea of 8" gate valve in 4' valve vault, 118 Ea water service connections, 125 LF remove and replace culvert, 300 LF of 12" water main quality storm sewer, 50 LF of 18" water main quality storm sewer, 14,000 SY topsoil furnish and place, and all other work necessary to complete the improvements.
Approx. 950 LF of 6", 3,350 LF of 8", and 20 LF of 12" diameter restrained joint water main replacement and 8 connections to the existing water system. The work also includes replacement of 97 water services, 7 fire hydrants, 7 blowoff assemblies, and 1 air and vacuum relief valve (ARV) assembly. Existing water main and appurtenances shall be filled and abandoned in place. Restoration includes trench patching, asphalt grind & overlay, curb, sidewalk & 35 ADA ramp replacements.
Posted Date
Jan 23, 2026
Due Date
Feb 18, 2026
Release: Jan 23, 2026
Close: Feb 18, 2026
Approx. 950 LF of 6", 3,350 LF of 8", and 20 LF of 12" diameter restrained joint water main replacement and 8 connections to the existing water system. The work also includes replacement of 97 water services, 7 fire hydrants, 7 blowoff assemblies, and 1 air and vacuum relief valve (ARV) assembly. Existing water main and appurtenances shall be filled and abandoned in place. Restoration includes trench patching, asphalt grind & overlay, curb, sidewalk & 35 ADA ramp replacements.