CityAL
Posted
Oct 27, 2026
Dec 8, 2026
Avenue C Water Main Replacement RFP
Approx. 3000 LF of 8inch Pipe, 500 LF of 6" Pipe. Piping and some fittings are owner supplied materials. Connections to the existing system along each side road.
Description: New water main will create a loop, improving water quality, as well as include 8 services to property owners on Y Avenue. The construction improvements include the construction of approx., 4,520 LF of trenched 6" water main, 460 LF of trenchless 6" water main, 8 water service connections, 5 fire hydrant assemblies, 6 valves, 2 connections to existing water main, 20 LF of 8" sanitary sewer removal and replacement, 390 LF of trenched storm sewer ranging from 12" to 36" in diameter, 151 SY of full depth HMA pavement patches, 417 SY of granular driveway and 86 SY of HMA driveway. Other associated improvements include fittings, traffic control, erosion control, surface restoration, and miscellaneous work necessary to complete the project. The alternate bid includes approx., 4,520 LF of trenched 8" water main and 460 LF of trenchless 8" water main as opposed to 6" water main. Other associated modifications include the replacement of 6" valves and fittings with 8" equivalents as necessary to complete the project.
City · IA, US
Solicitation files and supporting documents for this bid.
RFP documents aren’t available here yet.
Our team can help you find the original solicitation documents.
Request File RetrievalThese related opportunities are still open for bidding.
CityAL
Posted
Oct 27, 2026
Dec 8, 2026
Approx. 3000 LF of 8inch Pipe, 500 LF of 6" Pipe. Piping and some fittings are owner supplied materials. Connections to the existing system along each side road.
CityIL
Posted
Oct 2, 2026
Dec 1, 2026
Work includes construction of 8" and 6" water main installed by open cut construction methods, including: pavement removal; trench excavation; water main pipe materials and installation; valves and valve vaults; fire hydrant assemblies including hydrant and auxiliary valve; water service connections; abandonment of existing water main; sanitary sewer removal and replacement; storm sewer removal and replacement; pipe bedding; trench backfill; pavement replacement; driveway replacement; curb and gutter replacement; parkway restoration; traffic control; water main pressure testing and disinfection; and all other work necessary for a complete and functional water main installation as shown, specified, or required.
CityWI
Posted
Nov 3, 2026
Nov 20, 2026
1,620 LF of 8" dia. PVC Water Main, 90 LF of 6" dia. PVC Hydrant Lead/Water Main, 10 Each 8" Gate Valve & Box, 6 Each 6" Gate Valve & Box, 6 Each Hydrant, 840 LF of 1.25" dia. HDPE Water Service, 24 Each 1.25" Corporation Stop, 24 Each 1.25" Curb Stop and Box, Pavement and Turf Restoration, Pavement Marking, Erosion Control, and Traffic Control.
CityIL
Posted
Nov 12, 2026
Dec 1, 2026
Work generally consists of installation of approx., 1270 LF of 12" DI water main using open cut method. This work also includes the removal and/or capping of existing water mains of different sizes, installation of valves, hydrants, and fittings.