Sanitary Sewer Repair at 1608 Broadway in the City of Gary, IN.
Furnish all labor, materials, tools, equipment, superintendence, and all necessary incidentals for the repair of sanitary sewer pipe.
Manhole No. 507 Sewer Invert Depth is ± 13.7
Manhole No. 508 Sewer Invert Depth is ± 13.9
POINT REPAIR
Remove and replace existing 15-inch diameter pipe with 15-inch diameter PVC SDR 35 ± 30-linear feet from Manhole No. 508 going towards Manhole No. 507.
CIPP LINING
CIPP line existing 15-inch diameter pipe x 190 linear feet starting from Manhole No. 508 to Manhole No. 507.
POINT REPAIR
Remove and replace existing 15-inch diameter pipe with 15-inch diameter PVC SDR 35 ± 30-linear feet from Manhole No. 508 going towards Manhole No. 507.
Contractor shall ensure pipe penetrations are sealed and watertight.
Contractor shall connect new pipe to existing good pipe with a watertight connection. Connect new pipe to existing PVC pipe with neoprene rubber coupling with stainless steel straps or coupling provided by the manufacturer and approved by the owner. When adjoining new pipe to existing, the maximum space between the abutting pipes shall be 1/8 inches or less.
CIPP LINING
CIPP line existing 15-inch diameter pipe x 190 linear feet starting from Manhole No. 508 to Manhole No. 507.
The CIPP liner shall extend 4-inches into existing manholes.
The Contractor shall install a pre-liner and/or perform chemical grouting of infiltration points as necessary