The project consists of comprehensive water main, utility structure, sanitary sewer, and storm sewer system improvements, including 50 LF of 4" Ductile Iron Water Service Replacement; 100 LF of 6" Ductile Iron Water Main Replacement; 10,950 LF of 8" Ductile Iron Water Main Replacement; 15 LF of 12" Ductile Iron Water Main Replacement; 3 EA of Water Main Vertical Offset; 1 EA of 4" Gate Valve and Valve Box; 4 EA of 6" Gate Valve and Valve Box; 30 EA of 8" Gate Valve and Valve Box; 16 EA of Hydrant with 6" Gate Valve and Valve Box; 230 LF of 6" Ductile Iron Hydrant Lead; 5 EA of Permanent Blow-Off with Frame and Lid; 350 SY of 2" Thick Insulation; 148 EA of Reconnect Existing Water Service; 1 EA of Reconnect Existing Water Service, Long; 1 EA of Replace and Reconnect Water Service on Replacement Main, Short; 1 EA of Replace and Reconnect Water Service on Replacement Main, Long; 8 EA of Unknown Water Service Investigation; 7 EA of Water Service Abandonment; 28 EA of Abandon Existing Water Main; 200 LF of Televise Sanitary & Storm Sewer; 150 LF of Televise Sanitary Laterals; 8 EA of 48" Sanitary Structure Replacement; 1 EA of 48" Sanitary Structure Replacement with External Wrap; 1 EA of Sanitary Structure Invert/Bench Repair; 6 EA of 48" Sanitary Structure Barrel and/or Cone Section; 3 EA of 48" Sanitary Structure Adaptive Barrel and/or Cone Section; 21 EA of Sanitary Structure Chimney Repair; 38 EA of Sanitary Structure Frame and Lid; 1 LS of Install New 16" Butterfly Valve and Valve Box; 1 LS of Replace Valve and Valve Structure with New 16" Butterfly Valve and Valve Box; 1 EA of Replace Water Valve Structure with Valve Box; 2 EA of Water Valve Structure Chimney Repair; 1 EA of Water Valve Structure Frame and Lid; 17 EA of 48" Storm Structure Replacement; 3 EA of 60" Storm Structure Replacement; 1 EA of 72" Storm Structure Replacement; 10 EA of Storm Structure Invert/Bench Repair; 1 EA of 48" Storm Structure Barrel and/or Cone Section; 16 EA of Storm Structure Chimney Repair; 11 EA of Storm Structure Frame and Lid; 26 EA of Storm Inlet Replacement; 16 EA of Storm Inlet with Sump Replacement; 9 EA of Storm Inlet Bench/Invert Repair; 8 EA of Storm Inlet Chimney Repair; 1 EA of Storm Inlet Frame and Grate; 39 EA of Storm Inlet Grate Only; 1 LS of Connect New 8" Sanitary Sewer to Existing Sanitary Structure 17-120-M14; 176 LF of 8" SDR 35 PVC Sanitary Sewer Replacement; 1 EA of Reconnect Existing Sanitary Lateral to New 8" Sanitary Sewer; 176 LF of Televise New 8" Sanitary Sewer; 35 LF of Abandon Existing 8" Sanitary Sewer Using Flowable Fill; 2 LS of Lift Station Lid/Hatch Improvements; 287 LF of Replace Existing Storm Sewer with New 12" Reinforced Concrete Pipe (Class III or Class V); 522 LF of Install New 12" Reinforced Concrete Pipe (Class III or Class V); 42 LF of Remove Existing Storm Sewer Pipe; 2 EA of Install New 48" Storm Structure, Complete; 3 EA of Install New Storm Inlet with Sump, Complete; 1 EA of Remove Existing Storm Structure; and 809 LF of Televise New Storm Sewer.