Discover opportunities months before the RFP drops
Learn more →Retrieving RFP details
Starbridge can help you:
Pain points mentioned in board meetings and strategic plans
Instantly outline and draft all requirements
Bring in your USPs and exploit competitor gaps
Starbridge can help you:
Get ahead of RFPs — target accounts planning budget or ending contracts soon
Accounts with contract expirations, meetings mentioning your product, grants, budget changes and more
Starbridge.ai books 30 - 40% of leads into meetings
Premium
Access the largest public sector contact database
Premium
Get complete source documentation & analysis
Procure DESIGN-BUILD services to replace De-Ionized (DI) Water Filter Systems with a Reverse Osmosis (RO) water system.
Starbridge can help you:
Pain points mentioned in board meetings and strategic plans
Instantly outline and draft all requirements
Bring in your USPs and exploit competitor gaps
Starbridge can help you:
Get ahead of RFPs — target accounts planning budget or ending contracts soon
Accounts with contract expirations, meetings mentioning your product, grants, budget changes and more
Starbridge.ai books 30 - 40% of leads into meetings
Reverse osmosis and deionized water system service, The requirement is for the service and maintenance of a Mar Cor CWP and four Mar Cor portable RO machines. Services to be provided by contractor under this contract shall include furnishing preventive maintenance, parts, labor, intervening service calls/emergency repairs, lodging, technical telephone assistance, expert supervision and all other allied costs required to maintain and repair a Mar Cor CWP and four mobile RO machines, Perform system checks on 4 (four) Millenium portable RO system, Inspect and replace RO prefilters: Part #S15000, one filter for each of the Millenium’s monthly for a total of 48 filters per year. Contractor to provide filters. Replace filter, 5M, 10”, Part #ME40696, one filter for each of the Millenium’s monthly for a total of 24 filters per year. Contractor to provide filters. Inspect and replace 1 Carbon Block PTG-520, Part #4000-0073: one filter for each of the Millenium’s quarterly for a total of 16 filters annually. Contractor to provide carbon blocks. Replace Carbon Block PTG-520 quarterly, Part # 3027145; one filter for each of the Millenium’s quarterly for a total of 16 filters annually. Contractor to provide carbon blocks, Replace MHX membrane, Part #3028365; replace one membrane for each of the Millenium’s annually for a total of 4 membranes, Repair and maintenance of Acid Systems: This includes tanks, pumps, controls, tubing, and all fittings throughout including connections at wall boxes
Posted Date
Jan 16, 2026
Due Date
Jan 29, 2026
Premium
Access the largest public sector contact database
Premium
Get complete source documentation & analysis
Release: Jan 16, 2026
Close: Jan 29, 2026
Reverse osmosis and deionized water system service, The requirement is for the service and maintenance of a Mar Cor CWP and four Mar Cor portable RO machines. Services to be provided by contractor under this contract shall include furnishing preventive maintenance, parts, labor, intervening service calls/emergency repairs, lodging, technical telephone assistance, expert supervision and all other allied costs required to maintain and repair a Mar Cor CWP and four mobile RO machines, Perform system checks on 4 (four) Millenium portable RO system, Inspect and replace RO prefilters: Part #S15000, one filter for each of the Millenium’s monthly for a total of 48 filters per year. Contractor to provide filters. Replace filter, 5M, 10”, Part #ME40696, one filter for each of the Millenium’s monthly for a total of 24 filters per year. Contractor to provide filters. Inspect and replace 1 Carbon Block PTG-520, Part #4000-0073: one filter for each of the Millenium’s quarterly for a total of 16 filters annually. Contractor to provide carbon blocks. Replace Carbon Block PTG-520 quarterly, Part # 3027145; one filter for each of the Millenium’s quarterly for a total of 16 filters annually. Contractor to provide carbon blocks, Replace MHX membrane, Part #3028365; replace one membrane for each of the Millenium’s annually for a total of 4 membranes, Repair and maintenance of Acid Systems: This includes tanks, pumps, controls, tubing, and all fittings throughout including connections at wall boxes
AvailableLarge pure water system producing reverse osmosis (RO)/type 3 water.
Posted Date
Jan 20, 2026
Due Date
Feb 2, 2026
Release: Jan 20, 2026
Close: Feb 2, 2026
Large pure water system producing reverse osmosis (RO)/type 3 water.
AvailableFor the current manually operated reverse osmosis desalination system requirement.
Posted Date
Jan 14, 2026
Due Date
Jan 28, 2026
Release: Jan 14, 2026
Close: Jan 28, 2026
For the current manually operated reverse osmosis desalination system requirement.
AvailableThe City of Hutchinson, Minnesota, is soliciting bids for the procurement of reverse osmosis membrane elements and associated appurtenances for its water treatment plant. Bids are due by 1:00 pm CT on February 3, 2026, and must be submitted electronically through QuestCDN, where the bidding documents are available under project #10011901. Installation is to be performed by City staff, and bidding must follow the City’s formal requirements including a 5% bid security.
Posted Date
-
Due Date
Feb 3, 2026
Close: Feb 3, 2026
The City of Hutchinson, Minnesota, is soliciting bids for the procurement of reverse osmosis membrane elements and associated appurtenances for its water treatment plant. Bids are due by 1:00 pm CT on February 3, 2026, and must be submitted electronically through QuestCDN, where the bidding documents are available under project #10011901. Installation is to be performed by City staff, and bidding must follow the City’s formal requirements including a 5% bid security.
AvailableSurface intent from meeting minutes, budgets, and contract expirations. Influence RFP requirements before competitors ever see them.
See your top 10 upcoming opportunities on a demo →