Posted
Nov 24, 2026
Dec 9, 2026
Brand-name or Equal Teledyne Flir Camera RFP
Detector and Spectral Range: The camera shall incorporate an indium gallium arsenide (InGaAs) detector optimized for the 0.9–1.7 µm spectral band, with a minimum resolution of 640 × 512 pixels and a detector pitch of 15 µm. Optics: The system shall include a 35 mm SWIR lens with an F1.4 aperture and C-mount interface. Temperature Calibration: The camera shall support temperature measurement over a calibrated range of 400°C to 1,200°C using appropriate band-matched optics and filters. Integration Time: The camera shall support an integration time of 5 µs or less at the required operating mode. The vendor shall document the achievable integration time at full-frame and reduced-window resolutions. See attached file.