Helix Water District seeks bids to install an impressed-current cathodic protection system for the Aqueduct 1 pipeline, including drilling a deep anode well, installing anode columns and a rectifier assembly, and performing testing and inspection. The work must meet applicable NACE and NEC standards and has an estimated project duration of approximately 180 days.
Starbridge can help you:
Pain points mentioned in board meetings and strategic plans
Instantly outline and draft all requirements
Bring in your USPs and exploit competitor gaps
Starbridge can help you:
Get ahead of RFPs — target accounts planning budget or ending contracts soon
Accounts with contract expirations, meetings mentioning your product, grants, budget changes and more
Starbridge.ai books 30 - 40% of leads into meetings
No files attached to this RFP.
Many agencies add documentation later or require FOIA requests. Starbridge can automatically retrieve these files for you.
Installation of deep well anode bed, rectifier assembly, and appurtenances for an impressed current cathodic protection system.
Posted Date
Nov 7, 2025
Due Date
Dec 16, 2025
Release: Nov 7, 2025
Close: Dec 16, 2025
Installation of deep well anode bed, rectifier assembly, and appurtenances for an impressed current cathodic protection system.
AvailablePremium
Access the largest public sector contact database
Perform cathodic inspection services and submit a written report for the pumping stations. Repair the cathodic protection system. Perform stray current interference testing at a minimum of three locations along the 18 mile pumping station forcemain.
Posted Date
Nov 21, 2025
Due Date
Dec 17, 2025
Release: Nov 21, 2025
Close: Dec 17, 2025
Perform cathodic inspection services and submit a written report for the pumping stations. Repair the cathodic protection system. Perform stray current interference testing at a minimum of three locations along the 18 mile pumping station forcemain.
AvailableWork consists of removing and replacing four pumps in the ftw/www building and associated mechanical work. Existing motor control centers (mccs) and variable frequency drives (vfds) will be removed and salvaged. Six new vfds will be installed. New power panels and associated electrical work is included. In addition, the work includes the installation of 50+ cathodic protection test stations. There is approx 660 LF of internal joint bonding that is required in 36" diameter pipe. Approx., 300 LF of external joint bonding on 8" or 12" buried pipe is also required. Other work includes external joint bonding inside of structures, installation of dc blockers, installation of dielectric unions, installation of insulating flange kits, and installation of buried galvanic anodes.
Posted Date
Nov 19, 2025
Due Date
Jan 20, 2026
Release: Nov 19, 2025
Close: Jan 20, 2026
Work consists of removing and replacing four pumps in the ftw/www building and associated mechanical work. Existing motor control centers (mccs) and variable frequency drives (vfds) will be removed and salvaged. Six new vfds will be installed. New power panels and associated electrical work is included. In addition, the work includes the installation of 50+ cathodic protection test stations. There is approx 660 LF of internal joint bonding that is required in 36" diameter pipe. Approx., 300 LF of external joint bonding on 8" or 12" buried pipe is also required. Other work includes external joint bonding inside of structures, installation of dc blockers, installation of dielectric unions, installation of insulating flange kits, and installation of buried galvanic anodes.
AvailableRepair and upgrade the existing cathodic protection system for the AK warren water resource facility's 72-, 90-, and 120" effluent outfalls. Cast Iron pipe joints and manhole covers on the existing ocean outfalls are subject to corrosion in the marine environment. This work requires divers and remotely operated vehicles (ROVs) to replace the mechanical attachment anode system with newer technology that uses commercial-grade magnets to prevent detachment of the anode wiring. The anode system is designed to provide 50+ years of corrosion protection to extend the useful life of the outfalls.
Posted Date
Nov 6, 2025
Due Date
Dec 18, 2025
Release: Nov 6, 2025
Close: Dec 18, 2025
Repair and upgrade the existing cathodic protection system for the AK warren water resource facility's 72-, 90-, and 120" effluent outfalls. Cast Iron pipe joints and manhole covers on the existing ocean outfalls are subject to corrosion in the marine environment. This work requires divers and remotely operated vehicles (ROVs) to replace the mechanical attachment anode system with newer technology that uses commercial-grade magnets to prevent detachment of the anode wiring. The anode system is designed to provide 50+ years of corrosion protection to extend the useful life of the outfalls.