Discover opportunities months before the RFP drops
Learn more →Retrieving RFP details
Starbridge can help you:
Pain points mentioned in board meetings and strategic plans
Instantly outline and draft all requirements
Bring in your USPs and exploit competitor gaps
Starbridge can help you:
Get ahead of RFPs — target accounts planning budget or ending contracts soon
Accounts with contract expirations, meetings mentioning your product, grants, budget changes and more
Starbridge.ai books 30 - 40% of leads into meetings
Premium
Access the largest public sector contact database
Premium
Get complete source documentation & analysis
The Los Angeles Department of Water & Power (LADWP) is soliciting bids for a monitoring system and transformer. This Invitation for Bid (IFB) requires electronic submission through the LADWP eRSP portal, with a bid deadline of 1/30/2026 at 07:00 PM GMT‑3. No public documents are uploaded on the listing page.
Starbridge can help you:
Pain points mentioned in board meetings and strategic plans
Instantly outline and draft all requirements
Bring in your USPs and exploit competitor gaps
Starbridge can help you:
Get ahead of RFPs — target accounts planning budget or ending contracts soon
Accounts with contract expirations, meetings mentioning your product, grants, budget changes and more
Starbridge.ai books 30 - 40% of leads into meetings
No files attached to this RFP.
Many agencies add documentation later or require FOIA requests. Starbridge can automatically retrieve these files for you.
Transformer Monitoring Unit (TMU) Modules: -(1) Dissolved Gas Analysis (DGA) Monitoring: 9 gases (H2, CH4, C2H6, C2H4, C2H2, CO, CO2, O2, N2) + moisture. Uses photo-acoustic spectroscopy (PAS) technology for gas measurements. -(1) Bushing Monitoring: For 6 bushings with custom-fitted bushing adaptors. Measures capacitance, tan-delta, and partial discharge (including integral winding partial discharge). Capable of detecting actual high energy events/arcing (measuring range:-20Vpeak to +20Vpeak). -(1) Power Supply : 90-130VAC, 47-63Hz -(1) Modified Digital Input Module: MOD-16I CARD for connecting to Rugged R501. -(1) Standard Input/Output Module: Include digital inputs, temperature inputs, 24V ISO, current loop, AC inputs for load sense, and spares. Sensors/Devices: -(6) bushing adaptors with amoured twin axial signal cable (40m) each. -(1) load current sensor CT (20m) -(2) magnet mount PT100 sensors (20m) for top oil and LTC oil tank -(1) ambient temperature and relative humidity sensor Software: -TOTUSPRO Web + TOTUS PRO Desktop -Analytics Software Package - Thermal & moisture /end of life calculations with detailed diagnostics and analytics. -Capable of distinguishing between partial discharge and arcing in each individual bushing and internal winding phase simultaneously.
Posted Date
Nov 25, 2025
Due Date
Jan 30, 2026
Premium
Access the largest public sector contact database
Premium
Get complete source documentation & analysis
Release: Nov 25, 2025
Close: Jan 30, 2026
Transformer Monitoring Unit (TMU) Modules: -(1) Dissolved Gas Analysis (DGA) Monitoring: 9 gases (H2, CH4, C2H6, C2H4, C2H2, CO, CO2, O2, N2) + moisture. Uses photo-acoustic spectroscopy (PAS) technology for gas measurements. -(1) Bushing Monitoring: For 6 bushings with custom-fitted bushing adaptors. Measures capacitance, tan-delta, and partial discharge (including integral winding partial discharge). Capable of detecting actual high energy events/arcing (measuring range:-20Vpeak to +20Vpeak). -(1) Power Supply : 90-130VAC, 47-63Hz -(1) Modified Digital Input Module: MOD-16I CARD for connecting to Rugged R501. -(1) Standard Input/Output Module: Include digital inputs, temperature inputs, 24V ISO, current loop, AC inputs for load sense, and spares. Sensors/Devices: -(6) bushing adaptors with amoured twin axial signal cable (40m) each. -(1) load current sensor CT (20m) -(2) magnet mount PT100 sensors (20m) for top oil and LTC oil tank -(1) ambient temperature and relative humidity sensor Software: -TOTUSPRO Web + TOTUS PRO Desktop -Analytics Software Package - Thermal & moisture /end of life calculations with detailed diagnostics and analytics. -Capable of distinguishing between partial discharge and arcing in each individual bushing and internal winding phase simultaneously.
AvailableSeeking qualified vendors for remote temperature monitoring system.
Posted Date
Jan 5, 2026
Due Date
Jan 27, 2026
Release: Jan 5, 2026
Close: Jan 27, 2026
Seeking qualified vendors for remote temperature monitoring system.
AvailableProcure a networking security monitoring cloud-based system.
Posted Date
Jan 14, 2026
Due Date
Feb 5, 2026
Release: Jan 14, 2026
Close: Feb 5, 2026
Procure a networking security monitoring cloud-based system.
AvailableProcurement of fume monitoring system calibrations, inspections, and repairs.
Posted Date
Jan 1, 2026
Due Date
Mar 31, 2026
Release: Jan 1, 2026
Close: Mar 31, 2026
Procurement of fume monitoring system calibrations, inspections, and repairs.
AvailableSurface intent from meeting minutes, budgets, and contract expirations. Influence RFP requirements before competitors ever see them.
See your top 10 upcoming opportunities on a demo →