Get complete source documentation & analysis
The installation of six (6) new lavatories, relocation of two (2) existing lavatories, mounting of seven (7) exam lights throughout seven (7) rooms, and the reconfiguration of one large exam room into two smaller exam rooms within the outpatient surgery department’s clinical space. This will be inclusive of: installation of required ICRA barriers; cutting a rough-in for the lavatory out of the existing wall; piping, valving, and terminating the appropriate Hot Water (HW) and Cold Water (CW) pipes to each new lavatory; ground penetrating radar (GPR) of existing floor slab and subsequent core drilling for lavatory waste line; installation of new waste and vent pipes and connection to existing lines; pulling and installing the electrical connections for new lavatory fixtures; final mounting and connection of the lavatory; mounting and energizing a wall- mounted exam light in each new exam room; erecting, mudding, and painting a new dividing wall; Installation two duplex receptacles on the new dividing wall; installing a new door for exam room access; installing a new ceiling-mounted fire alarm speaker; installing a new return-air (RA) register and tying its associated ductwork into an existing RA trunk; reconfiguring and rearranging lighting in existing exam room as necessary; and patching, repair, and painting of entire wall in which the new lavatory was installed.
Starbridge can help you:
Pain points mentioned in board meetings and strategic plans
Instantly outline and draft all requirements
Bring in your USPs and exploit competitor gaps
Starbridge can help you:
Get ahead of RFPs — target accounts planning budget or ending contracts soon
Accounts with contract expirations, meetings mentioning your product, grants, budget changes and more
Starbridge.ai books 30 - 40% of leads into meetings
The Department of Veterans Affairs (VISN 21) issued Presolicitation 36C26126R0020 for construction services to install six new lavatories, relocate two existing lavatories, mount seven exam lights, and reconfigure one exam room into two at the VAMC Las Vegas (Project No. 593-26-305). The procurement is a total SDVOSB set-aside under NAICS 236220 with an estimated magnitude of $100,000–$250,000 and a 90-calendar-day period of performance from notice to proceed. Solicitation documents were noted as forthcoming on or around Feb 3, 2026; responses are due Jan 30, 2026 at 14:00 PST (2026-01-30T22:00:00Z).
Posted Date
Jan 20, 2026
Due Date
Jan 30, 2026
Release: Jan 20, 2026
Close: Jan 30, 2026
The Department of Veterans Affairs (VISN 21) issued Presolicitation 36C26126R0020 for construction services to install six new lavatories, relocate two existing lavatories, mount seven exam lights, and reconfigure one exam room into two at the VAMC Las Vegas (Project No. 593-26-305). The procurement is a total SDVOSB set-aside under NAICS 236220 with an estimated magnitude of $100,000–$250,000 and a 90-calendar-day period of performance from notice to proceed. Solicitation documents were noted as forthcoming on or around Feb 3, 2026; responses are due Jan 30, 2026 at 14:00 PST (2026-01-30T22:00:00Z).
AvailableThe U.S. Department of Veterans Affairs is soliciting responses for improvements to the Central Utility Plant at the VAMC Las Vegas, NV, including replacement of end-of-life equipment and provision of catwalk access to previously inaccessible serviceable equipment. The contractor must provide all labor, materials, equipment, and supervision in accordance with contract documents; the notice is listed as a Request for Information/solicitation. The SAM.gov posting includes multiple public attachments (solicitation document, SOW, specifications, drawings, wage determination) and lists Christopher Whipple as the point of contact.
Posted Date
Jan 14, 2026
Due Date
Feb 17, 2026
Release: Jan 14, 2026
Close: Feb 17, 2026
The U.S. Department of Veterans Affairs is soliciting responses for improvements to the Central Utility Plant at the VAMC Las Vegas, NV, including replacement of end-of-life equipment and provision of catwalk access to previously inaccessible serviceable equipment. The contractor must provide all labor, materials, equipment, and supervision in accordance with contract documents; the notice is listed as a Request for Information/solicitation. The SAM.gov posting includes multiple public attachments (solicitation document, SOW, specifications, drawings, wage determination) and lists Christopher Whipple as the point of contact.
The Department of Veterans Affairs Veterans Health Administration is seeking proposals for construction services to improve the Central Utility Plant at the VA Southern Nevada Healthcare System in Las Vegas, Nevada. This project will replace several pieces of equipment in the Central Utility Plant that are beyond their serviceable life. It will also provide catwalk access for existing serviceable equipment that is currently inaccessible in the existing plant configuration.
Posted Date
Jan 14, 2026
Due Date
Feb 9, 2026
Release: Jan 14, 2026
Close: Feb 9, 2026
The Department of Veterans Affairs Veterans Health Administration is seeking proposals for construction services to improve the Central Utility Plant at the VA Southern Nevada Healthcare System in Las Vegas, Nevada. This project will replace several pieces of equipment in the Central Utility Plant that are beyond their serviceable life. It will also provide catwalk access for existing serviceable equipment that is currently inaccessible in the existing plant configuration.
This work includes but is not limited to: Replacement of the heat recovery system in the boiler room. Replace the existing water softener copper piping with new stainless steel piping and add polisher for a redundant system. Reconfigure the non-return valve at the top of boiler #3 into a horizontal configuration. Replace the existing corroded condensate return/surge tank with a new stainless steel tank. Extend/connect catwalk above boiler room for access to air handlers. Replace windows with operable louvers in Boiler room above overhead door (interlock to close with fire alarm activation). Automate back-up pumps located in Building 5 basement Controls in Building 2 boiler room and connect to existing BMS/JCI system for controlling and status display. Automate fuel oil system located in Building 3 and locate controls in Building 2 boiler room. Integrate fuel tank system to Hayz Cleveland controls in Building 2 boiler room (9 tanks total only 4 tanks are currently showing on the system). Separate 2 of the 5 condenser pumps onto their own dedicated power source bank (MCC). Replace 5 existing condenser pumps with high efficiency double impeller or raise the cooling towers and extend screen wall around cooling tower yard.
Posted Date
Nov 18, 2025
Due Date
Feb 9, 2026
Surface intent from meeting minutes, budgets, and contract expirations. Influence RFP requirements before competitors ever see them.
See your top 10 upcoming opportunities on a demo →Premium
Access the largest public sector contact database
Premium
Get complete source documentation & analysis
Close: Feb 9, 2026
This work includes but is not limited to: Replacement of the heat recovery system in the boiler room. Replace the existing water softener copper piping with new stainless steel piping and add polisher for a redundant system. Reconfigure the non-return valve at the top of boiler #3 into a horizontal configuration. Replace the existing corroded condensate return/surge tank with a new stainless steel tank. Extend/connect catwalk above boiler room for access to air handlers. Replace windows with operable louvers in Boiler room above overhead door (interlock to close with fire alarm activation). Automate back-up pumps located in Building 5 basement Controls in Building 2 boiler room and connect to existing BMS/JCI system for controlling and status display. Automate fuel oil system located in Building 3 and locate controls in Building 2 boiler room. Integrate fuel tank system to Hayz Cleveland controls in Building 2 boiler room (9 tanks total only 4 tanks are currently showing on the system). Separate 2 of the 5 condenser pumps onto their own dedicated power source bank (MCC). Replace 5 existing condenser pumps with high efficiency double impeller or raise the cooling towers and extend screen wall around cooling tower yard.