Summary
Remove poles with electrical; Remove manhole - sanitary each1; 14 LF sawing concrete pavement (full depth); 79 LF sawing bituminous pavement (full depth); 74 LF remove curb and gutter; 956 SY remove bituminous pavement; salvage landscape rock; 175 CY rock excavation; 435 CY common excavation; 339 CY aggregate base (CV) class 5; 941 SY type SP 9.5 wear CRS mix(3;b) 2.0" thick; 941 SY type SP 12.5 non wr CRS mix(3;c)3.0" thick; connect to existing water main; connect to existing sanitary sewer; 93 LF 161-1/2" HDPE force main; 66 LF 172" HDPE water main; blowoff assembly; gate valve and box; gate valve and box; potholing/verify utility; sanitary sewer manhole; casting assembly - water tight; 78 LF concrete curb & gutter; removable bollard; install landscape; lighting unit type 1; light foundation design special; vendor receptacle box; service cabinet; equipment pad; 340 LF non-metallic conduit; 2,135 LF non-metallic conduit; 60 LF non-metallic conduit; 315 LF underground wire 1/c 300 AWG; 500 LF underground wire 1/c 6 AWG; 910 LF underground wire 1/c 8 AWG; 2,210 LF underground wire 1/c 10 AWG; 22 SY geotextile weed barrier fabric; 220 LF sediment control log type wood fiber; turf establishment; 306 LF solid line paint - white.