Summary
The Contractor shall design the program acknowledging that all SSGR candidates possess an advanced baseline of knowledge. Prior to attending this course, all candidates will have met the following requirements: Successfully completed the required 80 hours of SNT-TC-1A training in PAUT. Currently hold a UT Level II or Level III certification. The Contractor must provide instruction, hands-on application, and practical examinations utilizing the following equipment platforms to ensure strict compatibility with ongoing SSGR operations: Evident OmniScan X4 or X3 Series flaw detectors. Evident WeldSight™ Software for advanced data analysis. See attached file.