This RFP is for the construction of Phase II Water System Improvements.
Starbridge can help you:
Pain points mentioned in board meetings and strategic plans
Instantly outline and draft all requirements
Bring in your USPs and exploit competitor gaps
Starbridge can help you:
Get ahead of RFPs — target accounts planning budget or ending contracts soon
Accounts with contract expirations, meetings mentioning your product, grants, budget changes and more
Starbridge.ai books 30 - 40% of leads into meetings
Work consisting of a ringwall is considered suitable for the 14-ft diameter finished water tank. Subgrades for the finished water tank should consist of competent residuum or new compacted structural fill following the undercut of the loose stratum a materials. An allowable contact pressure of of 2,000 psf (net allowable soil bearing pressure) is anticipated for the finished water tank. A factor of safety of 3.0 should be considered against general shear failure for this condition
Posted Date
Dec 2, 2025
Due Date
Jan 20, 2026
Release: Dec 2, 2025
Close: Jan 20, 2026
Premium
Access the largest public sector contact database
Premium
Get complete source documentation & analysis
Work consisting of a ringwall is considered suitable for the 14-ft diameter finished water tank. Subgrades for the finished water tank should consist of competent residuum or new compacted structural fill following the undercut of the loose stratum a materials. An allowable contact pressure of of 2,000 psf (net allowable soil bearing pressure) is anticipated for the finished water tank. A factor of safety of 3.0 should be considered against general shear failure for this condition
AvailableMasonry restoration & improvements phase ii east elevation.
Posted Date
Jan 10, 2026
Due Date
Feb 3, 2026
Release: Jan 10, 2026
Close: Feb 3, 2026
Masonry restoration & improvements phase ii east elevation.
AvailableWWTP process, disinfection and electrical improvements, Phase II.
Posted Date
Dec 2, 2025
Due Date
Jan 27, 2026
Release: Dec 2, 2025
Close: Jan 27, 2026
WWTP process, disinfection and electrical improvements, Phase II.
AvailableWork consists of water systems improvements - phase 3.
Posted Date
Nov 20, 2025
Due Date
Jan 29, 2026
Release: Nov 20, 2025
Close: Jan 29, 2026
Work consists of water systems improvements - phase 3.
AvailableSurface intent from meeting minutes, budgets, and contract expirations. Influence RFP requirements before competitors ever see them.