Summary
Skylight restoration and replacement, cupola roof and lantern restoration, masonry wall repairs, roof cover replacement and associated asbestos abatement across five buildings at the College of Staten Island. Work includes but is not limited to the following: Building 1A: Replacement of masonry, windowsills and lintels, area lights and miscellaneous elements per drawings. Installation of new flashing, counter flashing, weeps, and brick to match existing. Building 1C: Replace (4) existing skylights and the surrounding roof cover down to the existing metal deck (deck to remain). Provide new roofing system, curb, flashing, and new prefabricated skylights. Remove deteriorated plywood, salvage copper shingles and discard building paper at rotunda. Provide new flashing, vapor barrier, plywood, and reinstall copper shingles. Replace expansion joints and glass block mortar joints at lantern. Building 1L: Replace all existing mortar joints and expansion joints at glass block lanterns. Replace existing sealant at base of lantern. Replace existing skylight components indicated. Remove and reinstall glass panels. Provide temporary protection below skylight and lanterns. Building 6S: Replace existing skylight and associated components down to concrete and steel substructure. Install new skylight as per drawings. Building 2A: Replace existing counterflashing and brick at masonry walls adjacent to skylight. Provide new flashing, counter flashing, weeps, and brick to match existing.