Discover Opportunities months before the RFP drops
Learn more →Retrieving RFP details
Starbridge can help you:
Pain points mentioned in board meetings and strategic plans
Instantly outline and draft all requirements
Bring in your USPs and exploit competitor gaps
Starbridge can help you:
Get ahead of RFPs — target accounts planning budget or ending contracts soon
Accounts with contract expirations, meetings mentioning your product, grants, budget changes and more
Starbridge.ai books 30 - 40% of leads into meetings
Premium
Access the largest public sector contact database
Premium
Get complete source documentation & analysis
The Los Angeles Department of Water & Power (LADWP) is soliciting bids for the provision of cable caps. Bids must be submitted electronically through LADWP's eRSP system; mail-in or hard-copy submissions will not be accepted. The solicitation has an advertised due date of December 15, 2025 and includes an amendment note directing bidders to view addenda on the eRSP system.
Starbridge can help you:
Pain points mentioned in board meetings and strategic plans
Instantly outline and draft all requirements
Bring in your USPs and exploit competitor gaps
Starbridge can help you:
Get ahead of RFPs — target accounts planning budget or ending contracts soon
Accounts with contract expirations, meetings mentioning your product, grants, budget changes and more
Starbridge.ai books 30 - 40% of leads into meetings
No files attached to this RFP.
Many agencies add documentation later or require FOIA requests. Starbridge can automatically retrieve these files for you.
Caps, cable end, black, virgin polyvinyl chloride, 1/2-inch inside diameter (plus or minus 1/32-inch), 1-3/4-inches inside length and 0. 090-inch minimum wall thickness. The caps shall be free of pinholes and voids with rounded corners and smooth surfaces durable and legible markings shall be provided on the outside end of each cap, showing the appropriate size in fractional inches. The caps shall meet the physical and aging requirements for polyvinyl chloride 60c insulation. Thermoplastic insulated wire and cable for the transmission and distribution of electrical energy, ipcea publication number s-61-402, national electric manufacturers association (nema) publication number wc5, as last revised. Furnished in containers of 100 each. ''molded devices'' #205021aq.
Posted Date
Nov 21, 2025
Due Date
Dec 15, 2025
Release: Nov 21, 2025
Close: Dec 15, 2025
Caps, cable end, black, virgin polyvinyl chloride, 1/2-inch inside diameter (plus or minus 1/32-inch), 1-3/4-inches inside length and 0. 090-inch minimum wall thickness. The caps shall be free of pinholes and voids with rounded corners and smooth surfaces durable and legible markings shall be provided on the outside end of each cap, showing the appropriate size in fractional inches. The caps shall meet the physical and aging requirements for polyvinyl chloride 60c insulation. Thermoplastic insulated wire and cable for the transmission and distribution of electrical energy, ipcea publication number s-61-402, national electric manufacturers association (nema) publication number wc5, as last revised. Furnished in containers of 100 each. ''molded devices'' #205021aq.
Premium
Access the largest public sector contact database
A digital proposal for caps and gowns services.
Posted Date
Oct 17, 2025
Due Date
Nov 3, 2026
Release: Oct 17, 2025
Close: Nov 3, 2026
A digital proposal for caps and gowns services.
AvailableProvide head wear - logoed hi vis caps and beanies.
Posted Date
Dec 4, 2025
Due Date
Dec 30, 2025
Release: Dec 4, 2025
Close: Dec 30, 2025
Provide head wear - logoed hi vis caps and beanies.
AvailableProvide cable replacement. Provide information to identify the cable type, including but not limited to: category 5e, 6, 6a, utp, singlemode, multimode, etc. Cable manufacturer and part number. Identifying all systimax cables. Cable length as reported by the test meter. Cable tr endpoints: identify the serving tr. Identify the rack, patch panel, and port number where each cable terminates. Identify the type of patch panel in the tr the cable is terminated to. Identify the location of the patch panel in the rack, or other location if the patch panel is not located in a rack. Labels shall be applied to all cables covered by this project. Labels shall be applied to all racks, cabinets, and copper patch panels in all telecommunication rooms that are part of this project. See outside link.
Posted Date
Nov 24, 2025
Due Date
Dec 19, 2025
Release: Nov 24, 2025
Close: Dec 19, 2025
Provide cable replacement. Provide information to identify the cable type, including but not limited to: category 5e, 6, 6a, utp, singlemode, multimode, etc. Cable manufacturer and part number. Identifying all systimax cables. Cable length as reported by the test meter. Cable tr endpoints: identify the serving tr. Identify the rack, patch panel, and port number where each cable terminates. Identify the type of patch panel in the tr the cable is terminated to. Identify the location of the patch panel in the rack, or other location if the patch panel is not located in a rack. Labels shall be applied to all cables covered by this project. Labels shall be applied to all racks, cabinets, and copper patch panels in all telecommunication rooms that are part of this project. See outside link.
AvailableSurface intent from meeting minutes, budgets, and contract expirations. Influence RFP requirements before competitors ever see them.
See your top 10 upcoming opportunities on a demo →Premium
Get complete source documentation & analysis