Learn more →Elementary school fire alarm replacement scope includes Replacement of the existing fire alarm system with new honeywell notifier Emergency voice system, Maintain complete operation of the existing fire alarm panel during the Installation of the new fire alarm panel, Install new fire alarm panel adjacent to the existing fire alarm panel. Existing Fire alarm panel to be used as a pull box. Install terminal strips in existing fire Alarm panel and connect new fire alarm wiring from terminal strips to new fire Alarm panel, The existing fire alarm system shall be kept operational while the new system is Being installed. Contractor shall provide a fire watch if existing system is not Operational at the end of each work day, When the new fire alarm system is complete and fully operational, then remove The existing fire alarm system completely. This includes existing panels, Dialers, power supplies, and devices. Return all existing fire alarm devices to Owner.
Posted Date
Dec 2, 2025
Due Date
Jan 6, 2026
Release: Dec 2, 2025
Close: Jan 6, 2026
Elementary school fire alarm replacement scope includes Replacement of the existing fire alarm system with new honeywell notifier Emergency voice system, Maintain complete operation of the existing fire alarm panel during the Installation of the new fire alarm panel, Install new fire alarm panel adjacent to the existing fire alarm panel. Existing Fire alarm panel to be used as a pull box. Install terminal strips in existing fire Alarm panel and connect new fire alarm wiring from terminal strips to new fire Alarm panel, The existing fire alarm system shall be kept operational while the new system is Being installed. Contractor shall provide a fire watch if existing system is not Operational at the end of each work day, When the new fire alarm system is complete and fully operational, then remove The existing fire alarm system completely. This includes existing panels, Dialers, power supplies, and devices. Return all existing fire alarm devices to Owner.
AvailableReplace the existing 600 kW APC Symmetra MW UPS (480 V) with a new 200 kW, 480Y/277 V, 3‑phase, 4‑wire UPS, including demolition of legacy equipment, new feeders, grounding, raceway, and integration with existing distribution panels DP‑UPSH and DP‑UPSL.
Posted Date
-
Due Date
Dec 18, 2025
Close: Dec 18, 2025
Replace the existing 600 kW APC Symmetra MW UPS (480 V) with a new 200 kW, 480Y/277 V, 3‑phase, 4‑wire UPS, including demolition of legacy equipment, new feeders, grounding, raceway, and integration with existing distribution panels DP‑UPSH and DP‑UPSL.
AvailableAdmin building "A" upgrade heat pumps.
Posted Date
Sep 17, 2025
Due Date
Oct 15, 2025
Release: Sep 17, 2025
Close: Oct 15, 2025
Admin building "A" upgrade heat pumps.