Discover Opportunities months before the RFP drops
Learn more →Berrien County solicits bids to furnish and install fence and gates for the Sheriff's Department facility at 2100 E Empire Ave, Benton Harbor, MI. Bidders must follow attached specifications, submit two copies of the bid, and include the required non–Iran-linked-business certification.
Posted Date
Dec 2, 2025
Due Date
Dec 17, 2025
Release: Dec 2, 2025
Close: Dec 17, 2025
Berrien County solicits bids to furnish and install fence and gates for the Sheriff's Department facility at 2100 E Empire Ave, Benton Harbor, MI. Bidders must follow attached specifications, submit two copies of the bid, and include the required non–Iran-linked-business certification.
AvailableSeeking bids for the Sheriff's Department (2100 E Empire) fence and gate.
Posted Date
Jun 18, 2025
Due Date
Dec 17, 2025
Release: Jun 18, 2025
Close: Dec 17, 2025
Seeking bids for the Sheriff's Department (2100 E Empire) fence and gate.
AvailableWork includes 12" dual wall solid HDPE storm sewer 261 LF; 18" dual wall solid HDPE storm sewer 100 LF; 48" dual wall perf. HDPE storm sewer 2371 LF; 18" C76 IV RCP storm sewer 70 LF; 24" C76 IV RCP storm sewer 100 LF; 36" C76 IV RCP storm sewer 30 LF; 48" C76 IV RCP storm sewer 278 LF; 60" C76 IV RCP storm sewer 64 LF; 2' dia. drainage structure (W/ 2' sump) 6 EA; 4' dia. Drainage structure (W/ 2' sump) 4 EA; 4' dia. Storm manhole 1 EA; 6' dia. Storm manhole 11 EA; 7' dia. Storm manhole 1 EA; 24" C76 IV RCP end section 1 EA; 48" C76 IV RCP end section 3 EA; 60" C76 IV RCP end section 2 EA; open drain cleanout and bank restoration 312 LF. See attached file.
Posted Date
Aug 29, 2025
Due Date
Sep 25, 2025
Release: Aug 29, 2025
Close: Sep 25, 2025
Work includes 12" dual wall solid HDPE storm sewer 261 LF; 18" dual wall solid HDPE storm sewer 100 LF; 48" dual wall perf. HDPE storm sewer 2371 LF; 18" C76 IV RCP storm sewer 70 LF; 24" C76 IV RCP storm sewer 100 LF; 36" C76 IV RCP storm sewer 30 LF; 48" C76 IV RCP storm sewer 278 LF; 60" C76 IV RCP storm sewer 64 LF; 2' dia. drainage structure (W/ 2' sump) 6 EA; 4' dia. Drainage structure (W/ 2' sump) 4 EA; 4' dia. Storm manhole 1 EA; 6' dia. Storm manhole 11 EA; 7' dia. Storm manhole 1 EA; 24" C76 IV RCP end section 1 EA; 48" C76 IV RCP end section 3 EA; 60" C76 IV RCP end section 2 EA; open drain cleanout and bank restoration 312 LF. See attached file.
More RFPs available with Premium →
Get alerted before the bid drops, know which RFPs to pursue, and generate compliant drafts with AI.
Premium
Access the largest public sector contact database
Premium
Get complete source documentation & analysis