Discover Opportunities months before the RFP drops
Learn more →Retrieving RFP details
Starbridge can help you:
Pain points mentioned in board meetings and strategic plans
Instantly outline and draft all requirements
Bring in your USPs and exploit competitor gaps
Starbridge can help you:
Get ahead of RFPs — target accounts planning budget or ending contracts soon
Accounts with contract expirations, meetings mentioning your product, grants, budget changes and more
Starbridge.ai books 30 - 40% of leads into meetings
Premium
Access the largest public sector contact database
Premium
Get complete source documentation & analysis
Cleanout and redevelopment of Well 19 by a qualified, Washington licensed and bonded drilling or pump contractor (Contractor). Well 19 is a 10" diameter well. 386 FT below ground surface (bgs). Per the well construction diagram, the screen assembly consists of: 5 FT of 6" diameter tailpipe (386 to 381 feet bgs); 25 feet of 6" diameter, pipe-size, 30-slot, stainless-steel screen (381 to 356 feet bgs); 10 feet of 6" diameter blank casing (356 to 346 feet bgs); 5 feet of 6" diameter, pipe-size, 30-slot, stainless-steel pressure relief screen; and 10 feet of 6" diameter blank riser casing. A filter pack of 10-20 Colorado Silica sand is installed around the production screens and up between the 10-inch-diameter casing and screen assembly to provide a filter-pack reserve. Prior video surveys observed approximately 10 feet of sediment accumulation in the bottom the lower portion of the 6-inch-diameter screen assembly. The static water level in Well 19 was 191 feet bgs on July 23, 2025, and the specific capacity was 0.92 gallons per minute (gpm) per foot of drawdown at pumping rate 90 gpm.
Starbridge can help you:
Pain points mentioned in board meetings and strategic plans
Instantly outline and draft all requirements
Bring in your USPs and exploit competitor gaps
Starbridge can help you:
Get ahead of RFPs — target accounts planning budget or ending contracts soon
Accounts with contract expirations, meetings mentioning your product, grants, budget changes and more
Starbridge.ai books 30 - 40% of leads into meetings
Redevelopment of Production Well 8-3 as per Technical Specifications, Pump Testing, and Reinstallation of Original Pumping Equipment. Development of Test Well TB-8-3R as per Technical Specifications and Pump Testing.
Posted Date
Dec 9, 2025
Due Date
Jan 6, 2026
Release: Dec 9, 2025
Close: Jan 6, 2026
Redevelopment of Production Well 8-3 as per Technical Specifications, Pump Testing, and Reinstallation of Original Pumping Equipment. Development of Test Well TB-8-3R as per Technical Specifications and Pump Testing.
AvailableOrange County Water District seeks qualified firms to provide injection well redevelopment services for three types of recycled-water injection wells (Legacy, Modern, Mid Basin) in Orange County, CA. Contract: General Services Agreement (minimum 3-year term with a 2-year renewal option) for work initiated via itemized work orders. Gating requirements: attendance at a mandatory pre-proposal site meeting (required to submit), California DIR registration, Class A contractor license, compliance with California prevailing wage laws, and acceptance of OCWD’s standard Services Agreement. Technical minimums include lead operators with ≥5 years airlifting/reverse-circulation experience and specified high-flow experience (300–500+ gpm depending on well type). Submittal requirements include three hard copies plus one electronic flash drive; evaluation weighting: 50 pts experience/team, 25 pts past performance, 25 pts price.
Posted Date
Dec 4, 2025
Due Date
Jan 26, 2026
Release: Dec 4, 2025
Close: Jan 26, 2026
The Township of Parsippany-Troy Hills seeks a contractor to redevelop Production Well 8-3 and to develop Test Well TB-8-3R, including pump testing and reinstallation of original pumping equipment in accordance with technical specifications. Bid documents are available from the Township Purchasing Office for a nonrefundable fee; bidders must comply with applicable New Jersey statutes and regulations. Sealed bids are due by 10:00 AM ET on January 6, 2026 at the Township Purchasing Office.
Posted Date
-
Due Date
Jan 6, 2026
Close: Jan 6, 2026
The Township of Parsippany-Troy Hills seeks a contractor to redevelop Production Well 8-3 and to develop Test Well TB-8-3R, including pump testing and reinstallation of original pumping equipment in accordance with technical specifications. Bid documents are available from the Township Purchasing Office for a nonrefundable fee; bidders must comply with applicable New Jersey statutes and regulations. Sealed bids are due by 10:00 AM ET on January 6, 2026 at the Township Purchasing Office.
Provide redevelopment of an existing 19-acre rental assistance demonstration (rad) development.
Posted Date
Oct 26, 2025
Due Date
Dec 12, 2025
Release: Oct 26, 2025
Close: Dec 12, 2025
Provide redevelopment of an existing 19-acre rental assistance demonstration (rad) development.
Surface intent from meeting minutes, budgets, and contract expirations. Influence RFP requirements before competitors ever see them.
See your top 10 upcoming opportunities on a demo →Premium
Access the largest public sector contact database
Premium
Get complete source documentation & analysis
Orange County Water District seeks qualified firms to provide injection well redevelopment services for three types of recycled-water injection wells (Legacy, Modern, Mid Basin) in Orange County, CA. Contract: General Services Agreement (minimum 3-year term with a 2-year renewal option) for work initiated via itemized work orders. Gating requirements: attendance at a mandatory pre-proposal site meeting (required to submit), California DIR registration, Class A contractor license, compliance with California prevailing wage laws, and acceptance of OCWD’s standard Services Agreement. Technical minimums include lead operators with ≥5 years airlifting/reverse-circulation experience and specified high-flow experience (300–500+ gpm depending on well type). Submittal requirements include three hard copies plus one electronic flash drive; evaluation weighting: 50 pts experience/team, 25 pts past performance, 25 pts price.
Available