Discover Opportunities months before the RFP drops
Learn more →Retrieving RFP details
Starbridge can help you:
Pain points mentioned in board meetings and strategic plans
Instantly outline and draft all requirements
Bring in your USPs and exploit competitor gaps
Starbridge can help you:
Get ahead of RFPs — target accounts planning budget or ending contracts soon
Accounts with contract expirations, meetings mentioning your product, grants, budget changes and more
Starbridge.ai books 30 - 40% of leads into meetings
Premium
Access the largest public sector contact database
Premium
Get complete source documentation & analysis
Construct a 20,000 SF steel spec building.
Starbridge can help you:
Pain points mentioned in board meetings and strategic plans
Instantly outline and draft all requirements
Bring in your USPs and exploit competitor gaps
Starbridge can help you:
Get ahead of RFPs — target accounts planning budget or ending contracts soon
Accounts with contract expirations, meetings mentioning your product, grants, budget changes and more
Starbridge.ai books 30 - 40% of leads into meetings
No files attached to this RFP.
Many agencies add documentation later or require FOIA requests. Starbridge can automatically retrieve these files for you.
Construct a four-span steel beam structure with concrete deck. See outside link.
Posted Date
Dec 9, 2025
Due Date
Jan 16, 2026
Release: Dec 9, 2025
Close: Jan 16, 2026
Construct a four-span steel beam structure with concrete deck. See outside link.
AvailablePremium
Access the largest public sector contact database
The project consists of construction of a 12,000 SF speculative building on an existing concrete pad.
Posted Date
Dec 3, 2025
Due Date
Dec 22, 2025
Release: Dec 3, 2025
Close: Dec 22, 2025
The project consists of construction of a 12,000 SF speculative building on an existing concrete pad.
AvailableDESIGN-BUILD: Shipping and Receiving Building. Construct a Shipping and Receiving Building. Primary facilities include the shipping and receiving facility with high bay warehouse space, administrative space, and loading dock, and organizational vehicle parking. Project includes building information systems, antiterrorism/force protection measure, fire protection and alarm systems, and Energy Monitoring Control Systems (EMCS) connection. Supporting facilities include utility (electric, water, sewer, and gas) connections, exterior lighting, paving, parking, storm drainage, landscaping, site improvements, and information systems. Post Construction Award Services (PCAS) will be included in the project. Heating and air conditioning will be provided by self-contained system. Measures in accordance with the Department of Defense (DoD) Minimum Antiterrorism for Buildings standards will be provided. Comprehensive building and furnishings-related interior design services are required. Access for individuals with disabilities will be provided. Cybersecurity Measures will be incorporated into this project. Sustainability/Energy measures will be provided. Facilities will be designed to a minimum life of 40 years in accordance with DoD's Unified Facilities Criteria (UFC 1-200-02) including energy efficiencies, building envelope and integrated building systems performance. Air Conditioning (Estimated 40 Tons).
Posted Date
Oct 27, 2025
Due Date
Nov 11, 2029
Release: Oct 27, 2025
Close: Nov 11, 2029
DESIGN-BUILD: Shipping and Receiving Building. Construct a Shipping and Receiving Building. Primary facilities include the shipping and receiving facility with high bay warehouse space, administrative space, and loading dock, and organizational vehicle parking. Project includes building information systems, antiterrorism/force protection measure, fire protection and alarm systems, and Energy Monitoring Control Systems (EMCS) connection. Supporting facilities include utility (electric, water, sewer, and gas) connections, exterior lighting, paving, parking, storm drainage, landscaping, site improvements, and information systems. Post Construction Award Services (PCAS) will be included in the project. Heating and air conditioning will be provided by self-contained system. Measures in accordance with the Department of Defense (DoD) Minimum Antiterrorism for Buildings standards will be provided. Comprehensive building and furnishings-related interior design services are required. Access for individuals with disabilities will be provided. Cybersecurity Measures will be incorporated into this project. Sustainability/Energy measures will be provided. Facilities will be designed to a minimum life of 40 years in accordance with DoD's Unified Facilities Criteria (UFC 1-200-02) including energy efficiencies, building envelope and integrated building systems performance. Air Conditioning (Estimated 40 Tons).
AvailableBuilding, prefabricated, steel *building specifications* width: 40' feet length: 100' feet height: 16' feet color: medium blue roof: standing seam roof roof pitch: 2:12 roof type: 26-gauge purlin bearing rib (pbr) wall type: 26-gauge purlin bearing rib (pbr) frame openings: - 2 each 14' x 12' feet - 2 each 3' x 7' feet access doors: - 2 each 14' x 12' roll up doors - 2 each 3' x 7' man doors *requested building codes* building code: ibc 24 wind load: 115 mph wind exposure: b ground snow load: 0 psf roof snow load: 0 psf collateral load: 1 psf live load (reducible): 20 psf *accessories* gutters & downspouts: yes *features* - 26-gauge purlin bearing rib ("pbr") roof system to provide full overlap between sheets and prevent leakage - az55 galvalume roof coating to provide high resistance to rust - 26-gauge painted sidewall panels with a galvanized coating beneath the paint - 16-gauge galvanized framing to prevent rust, warping and bending - heavy 16-gauge galvanized base angle to seal the bottom of the building against leaks - 26-gauge interior partition panels sheeted on one side - complete commercial trim package to cover the cut edges of the wall panels around door openings, the galvanized jambs and the galvanized header - stamped, sealed engineering drawings by professional engineers *warranty* - 40-year limited rust-through perforation warranty on unpainted pbr roof panels with az55 galvalume coating - 40-year limited paint warranty against cracking, flaking or peeling- 30-year limited paint warranty against chalking and fading - 60-year warranty on steel beams (suitability of beams for local seismic, snow and wind loads in effect at time of order) "olympia steel buildings", 1 each.
Posted Date
Dec 8, 2025
Due Date
Dec 18, 2025
Release: Dec 8, 2025
Close: Dec 18, 2025
Building, prefabricated, steel *building specifications* width: 40' feet length: 100' feet height: 16' feet color: medium blue roof: standing seam roof roof pitch: 2:12 roof type: 26-gauge purlin bearing rib (pbr) wall type: 26-gauge purlin bearing rib (pbr) frame openings: - 2 each 14' x 12' feet - 2 each 3' x 7' feet access doors: - 2 each 14' x 12' roll up doors - 2 each 3' x 7' man doors *requested building codes* building code: ibc 24 wind load: 115 mph wind exposure: b ground snow load: 0 psf roof snow load: 0 psf collateral load: 1 psf live load (reducible): 20 psf *accessories* gutters & downspouts: yes *features* - 26-gauge purlin bearing rib ("pbr") roof system to provide full overlap between sheets and prevent leakage - az55 galvalume roof coating to provide high resistance to rust - 26-gauge painted sidewall panels with a galvanized coating beneath the paint - 16-gauge galvanized framing to prevent rust, warping and bending - heavy 16-gauge galvanized base angle to seal the bottom of the building against leaks - 26-gauge interior partition panels sheeted on one side - complete commercial trim package to cover the cut edges of the wall panels around door openings, the galvanized jambs and the galvanized header - stamped, sealed engineering drawings by professional engineers *warranty* - 40-year limited rust-through perforation warranty on unpainted pbr roof panels with az55 galvalume coating - 40-year limited paint warranty against cracking, flaking or peeling- 30-year limited paint warranty against chalking and fading - 60-year warranty on steel beams (suitability of beams for local seismic, snow and wind loads in effect at time of order) "olympia steel buildings", 1 each.
AvailableSurface intent from meeting minutes, budgets, and contract expirations. Influence RFP requirements before competitors ever see them.
See your top 10 upcoming opportunities on a demo →Premium
Get complete source documentation & analysis